One very successful trick I use to simulate radiated immunity on the bench is to run an RF generator into an H-field (loop) probe. The best level seems to be +15 to +20 dBm. This will generate an ...
The APSIN6000 portable RF signal generator specifies a phase noise -128 dBc/Hz at 1 GHz and a 20 kHz offset, harmonics of less than -40 dBc, and a resolution of 0.001 Hz from 9 kHz up to 6.4 GHz. An ...
I’ve always been an advocate of harmonic comb generators for everything from validating emissions measurements to using them as controlled harmonic sources for various measurements and experiments ...